Permatile
5'-0" × 3'-0" × 58'-0" Single Cell Box Culvert
Generate PDF
Cross Section
Standard Unit
Inlet Unit
Outlet Unit
REINFORCEMENT CROSS SECTION
5'-0" × 3'-0" BOX CULVERT · SINGLE CELL
℄
C1 #4
A1 #4 @ 8" O.C.
B1 #4 @ 8" O.C.
C100 #4
A2 #4 @ 8" O.C.
C200 #4
B3 #4 @ 8" O.C.
A100 #4 @ 8" O.C.
A300 #4 @ 8" O.C.
A200 #4 @ 8" O.C.
A400 #4 @ 8" O.C.
8"
8"
5'-0"
5'-0"
8"
8"
6'-4"
6'-4"
8"
8"
3'-0"
3'-0"
8"
8"
4'-4"
4'-4"
8"
8"
MATERIAL NOTES
f'c = 5,000 PSI
fy = 60,000 PSI (ASTM A615)
Cover — Top Ext.: 2 1/2"
Top Int.: 2"
All Other: 1 1/2"
SCALE
0
1'-0"
−
100%
+
PERMATILE / ENGINEERING CANVAS
5'-0" × 3'-0" × 58'-0"
Single Cell Box Culvert
14 units
·
VDOT
·
draft
Geometry
Design Standard
VDOT Standard Sizes
✓ 5'×3'
▼
Structure Type
Cell Count
Clear Span
"
Clear Rise
"
Wall Thickness
"
Top Slab
"
Bottom Slab
"
Haunch Width
"
Haunch Height
"
Fill Height
"
Skew Angle
deg
Units
14 units / 58'-0"
Unit Length
"
Total Length
"
Standard Units
Inlet Units
Outlet Units
Materials
5000 PSI / Gr 60
f'c (psi)
psi
Rebar Grade
Rebar Spec
Concrete Cover
Top Slab Ext.
"
Top Slab Int.
"
Bot. Slab Ext.
"
Bot. Slab Int.
"
Wall Ext.
"
Wall Int.
"
Rebar
11 bars
Mark
Size
Qty
Spc
Length
Shape
Zone
Steel
Add Bar
Project
Blue Ridge Parkway Box Culvert
Project Name
Client Name
Project Number
State Standard
Location
Engineer
Drawn By
Checked By
Approved By
Status
Computed Values
Outside Width
6'-4"
Outside Height
4'-4"
Concrete / Unit
1.712
CY
Steel / Unit
186
lbs
Unit Weight
7,120
lbs
Total Units
14
Total Concrete
23.97
CY
Total Steel
2,607
lbs
Validation
1 warning